=== A Master List of US-Sponsored Magnetometers ===
+
=== A Master List of US-Sponsored Magnetometers* ===
 +
 
 +
{| class="wikitable" style="width: 50%; height: 4em;"
 +
|-
 +
| Array || Location || Instruments || Manufacturer || No. of Locations
 +
|-
 +
| AAL-PIP || Antarctica || Fluxgate || Korepanov || 6
 +
|-
 +
| AAL-PIP || Antarctica || Induction Coil || UNH || 4
 +
|-
 +
| AMBER || Africa || Fluxgate || UCLA || 7
 +
|-
 +
| AMBER || South America || Fluxgate || UCLA || 2
 +
|-
 +
| AMBER || East Asia || Fluxgate || UCLA || 4
 +
|-
 +
| Falcon || Continental US || Fluxgate || UCLA || 11
 +
|-
 +
| GIMA || Alaska || Fluxgate || Narod || 9
 +
|-
 +
| Jicamarca || South America || Fluxgate || UCLA || 2
 +
|-
 +
| LISN || South America || Fluxgate || UCLA || 6
 +
|-
 +
| MACCS || Arctic Canada || Fluxgate || Narod || 8
 +
|-
 +
| McMAC || Continental US & Mexico || Fluxgate || UCLA || 9
 +
|-
 +
| MEASURE || Continental US || Fluxgate || UCLA || 6
 +
|-
 +
| SAMBA || South America & Antarctica || Fluxgate || UCLA || 12
 +
|-
 +
| THEMIS || Continental US & Canada || Fluxgate || UCLA || 24
 +
|-
 +
| US Geological Survey || US & Territories || Fluxgate || Narod || 11
 +
|-
 +
| NJIT / AGO || Antarctica || Fluxgate || Bell Labs || 7
 +
|-
 +
| NJIT / AGO || Antarctica || Induction Coil || Tohoku University || 5
 +
|-
 +
| MICA || Antarctica || Induction Coil || UNH || 5
 +
|-
 +
| MICA || Arctic Canada || Induction Coil || UNH || 4
 +
|-
 +
| MICA || Svalbard || Induction Coil || UNH || 4
 +
|}
 +
 
 +
*Some stations listed here are not currently operating.
  
 
== Autonomous Adaptive Low-Power Instrument Platform (AAL-PIP) ==
 
== Autonomous Adaptive Low-Power Instrument Platform (AAL-PIP) ==

Revision as of 16:24, 27 May 2019

Greenbelt, Maryland May 5-6, 2016

For discussion of the current state and future of ground magnetometer arrays in support of space weather monitoring and research, see article in Space Weather.

A Master List of US-Sponsored Magnetometers*

Array Location Instruments Manufacturer No. of Locations
AAL-PIP Antarctica Fluxgate Korepanov 6
AAL-PIP Antarctica Induction Coil UNH 4
AMBER Africa Fluxgate UCLA 7
AMBER South America Fluxgate UCLA 2
AMBER East Asia Fluxgate UCLA 4
Falcon Continental US Fluxgate UCLA 11
GIMA Alaska Fluxgate Narod 9
Jicamarca South America Fluxgate UCLA 2
LISN South America Fluxgate UCLA 6
MACCS Arctic Canada Fluxgate Narod 8
McMAC Continental US & Mexico Fluxgate UCLA 9
MEASURE Continental US Fluxgate UCLA 6
SAMBA South America & Antarctica Fluxgate UCLA 12
THEMIS Continental US & Canada Fluxgate UCLA 24
US Geological Survey US & Territories Fluxgate Narod 11
NJIT / AGO Antarctica Fluxgate Bell Labs 7
NJIT / AGO Antarctica Induction Coil Tohoku University 5
MICA Antarctica Induction Coil UNH 5
MICA Arctic Canada Induction Coil UNH 4
MICA Svalbard Induction Coil UNH 4
  • Some stations listed here are not currently operating.

Autonomous Adaptive Low-Power Instrument Platform (AAL-PIP)

Fluxgates

Station Geographic Latitude Geographic Longitude Instrument Type Sampling Rate Data Coverage Publicly Accessible
PG0 -83.67 88.68 Korepanov 1 Hz 2015-present Yes
PG1 -84.50 77.20 Acuna 1 Hz 2008-present Yes
PG2 -84.42 57.96 Korepanov 1 Hz 2013-present Yes
PG3 -84.81 37.63 Korepanov 1 Hz 2013-present Yes
PG4 -83.34 12.25 Korepanov 1 Hz 2014-present Yes
PG5 -81.96 5.71 Korepanov 1 Hz 2016-present Yes

Induction

Station Geographic Latitude Geographic Longitude Instrument Type Sampling Rate Data Coverage Publicly Accessible
PG2 -84.42 57.96 Lessard 10 Hz 2013-present Yes
PG3 -84.81 37.63 Lessard 10 Hz 2013-present Yes
PG4 -83.34 12.25 Lessard 10 Hz 2014-present Yes
PG5 -81.96 5.71 Lessard 10 Hz 2016-present Yes